PAS

Pull Rope Emergency Stop Switches

Article Number: 91.057 560.xxx

  • Single-side Installation
  • Plastic-Enclosure
  • Reset knob

Features

Kiepe pull-rope emergency stop switches type PAS are used in accordance with the requirements of EN 620 as well as BGI 710 and in conformity with DIN EN ISO 13850 as emergency stop devices as supplementary safety measures on conveyor belt systems and finishing and processing machines. The pull rope is tensioned on one side of the actuating shaft. With the KIEPE pull-rope-system functionally aligned, the emergency stop signal can be triggered over a distance of 30 m with a maximum temperature variation of +/-20°C in the application. Less temperature variation allows a longer installation length f.ex. for applications in production halls. Kiepe pull rope emergency stop switches type PAS comply with Machinery Directive 2006/42/EG. The device must only be used in electrical control circuits.

The PAS plastic housing is equipped with 1 SPDT and 1 N.C. contact (positive opening). Taking into consideration the safety data and maintenance recommendations, the pull rope emergency stop switch type PAS can be used in safety circuits in accordance with DIN EN ISO 13849 up to Performance Level d (PLd). 

Corrosive

Powder
Suitable
Gravel
Not Suitable
Rubble
Not Suitable

Non-Corrosive

Powder
Suitable
Gravel
Not Suitable
Rubble
Not Suitable

The emergency stop signal can be activated by pulling or breaking of the pull wire or by pushing the blue emergency stop button when the switch is correctly adjusted. The spacer tool helps to find the correct operating position for a proper work and has to be removed after adjustment. The microswitches are actuated by a spring supported cam disc at the same time. The emergency stop signal is performed with positive-making normally closed (NC) contacts in accordance with the closed circuit principle. After the emergency stop function is triggered, the switching mechanism is locked in the shut-off position “0“. The blue reset button can only be removed to position “1“, when the actuating shaft is back in operating position. In position “1“, the switching contacts are reactivated and the conveyor belt is prepared for start up the belt conveyor.

Note: 
Resetting the pull rope emergency stop switch must not cause in starting up the conveyor system. 

General

DesignationPull rope emergency stop switch type PAS
emergency stop device with latching function
 
Type of actuationPull rope - single-side installation, integrated wire-break detection 
Complies withDIN EN 60947-5-5; IEC 60947-5-5 
Suited forControl circuits in accordance with DIN EN 60204 -1 
Pull rope length
(with external spring)
1x 30 m at 40 Kelvin
1x 50 m at 25 Kelvin
1x 75 m at 17 Kelvin
 


Mechanics

 
EnclosureThermoplastic, yellow, similar to RAL 1004 
Reset buttonPARA, blue, similar to RAL 5010 
Fixation4 x M6 
Net Weight (typic)0.4 kg 


Electrical system

Switching systemPositive-opening snap-action switches; according DIN EN 60947-5-1; cam operated 
Cable entries3x M20 x 1.5 threaded holes with
1x cable gland (sealing Ø 6 mm ...Ø 12 mm)
2x Dummy screw
 
Utilization category Ue/IeAC-15: 230 V / 1.5 A
DC-13: 24 V / 2.0 A
 
Connection cross section (max.)2.5 mm2 
Protective conductor connectionProtection class II / Protective Insulation 
Rated insulation voltage Ui250 V 
Rated impulse withstand voltage Uimp2.5 kV, Degree of Pollution III 
Conventional thermal current Ith6 A 


Ambient conditions in accordance with DIN EN 60947-5-5

Ambient Temperature-25°C ... + 70°C 
Enclosure Protection Rating (EN 60529)IP65 


Reliability and Safety Data

Electrical reliabilityDC-13: 24 V / 2 A              B10d = 200.000 cycles
AC-15: 230 V / 1.5 A        B10d = 840.000 cylces
 
Mechanical reliability840.000 cycles 

Safety classification 
(depending upon system architecture / Variants with minimum 2 Normally closed contacts)

 

DIN EN ISO 13849-1 (up to PLd)
DIN EN 62061 (up to SIL 2)
 

Pull-rope emergency stop switches of type PAS are fastened to the substructure in the installation position using 4 M6 screws each. The electrical connection is made when the device is open via the cable gland included in the scope of delivery to the connection terminals of a circuit board. The pull rope is tensioned with the tension spring between the anchor hook and the mounting ring of the switch until the spacer can be easily removed from the switch. This is the operating point. The switch can only be reset at the operating point. The spacer must be removed and the bellow be attached to the housing.

Note:
The tension springs are designed for cable systems with Kiepe devices at the recommended temperature changes in a straight installation.

Variants

Name Ordering No. Weight Contacts
NC
NO
SPDT
PAS 001 91.057 560.001 0.5 kg / 1 Unit
1
1
PAS 101 Metall parts stainless steel, Plastic bearing 91. 057 650.101 0.5 kg / 1 Unit
1
1

Downloads

Data sheet – PAS

PDF1 MB

download

Components for Pull Rope Installation

PDF2 MB

download

EU Declaration of Conformity – PAS

PDF438 KB

download