HER EX

ATEX Limit Switch

Article Number: 2D: 92.096 173.xxx; 3D: 92.096.606.xxx

  • Alu housing
  • Brass roller Ø 50 mm
  • Adjustable prewarning
  • Without latching

Features

The HER EX limit switches are used to monitor the end position of moving machine parts. With at least two switching points a signal can be used for a pre-warning. The HER EX limit switches are suitable for use in transportation, conveying, loading and mixing systems for bulk materials and are intended for use in fixed installations. In the installation position they are triggerd from one side. The KIEPE limit switches Type HER EX are suited for use in explosive atmosphere with conductive dust, Group II, category 2 , in zone 21 and 22 (Type HER EX 2D) or category 3, only in zone 22 (Type HER EX 3D). The Kiepe limit switch Type HER EX complies with the ATEX Directive 2014/34/EU and meets the safety objectives of the Low Voltage Directive 2014/35/EU and IECEx. The switch Type HER EX features a robust aluminum housing and is equipped with up to 4 force-actuated changeover contacts with snap-action function with two settable switching points. 

Note: 
The limit switch must only be used in electrical control circuits

The limit switch type HER EX operates when the actuating roller is approached and deflected by the machine part in the direction of rotation of the roller lever. The switching angle can be set for each switching contact by means of an adjustable cam roller. In addition to the safety cut-out this also enables an advance warning to be realized. When the machine part is reset, the roller lever returns automatically.

General

DesignationLimit Switch Type HER EX 
Type of actuationBidirectional (double-side) via roller lever 
Complies withEN 60947-5-1; EN IEC 60079-31; (EN IEC 60079-0) 
Suited forControl units in accordance with DIN EN 60204-1 


ATEX/ IECEx

 
Device group / device categoryII/ 2D, 3D; flammable, conductive dust 
Type of protectionProtection through housing 
for Zone 21,22   HER EX II 2DL II 2D Ex tb IIIC T85°C Db IP67 
for Zone 22        HER EX II 3DL II 3D Ex tc IIIC T85°C Dc IP67 
CertificatesEPS 12 ATEX 1 479 X, IECEx EPS 14.0040X 


Mechanics

 
EnclosureAluminum 
CoatingPU 2K-paint; Enclosure – yellow (RAL 1004) 
Actuating leverBrass 
Mounting+/- 75° 
Deflection of roller lever (max.)2 x M8 
Weight1.9 kg 


Electrical system

Switching system (max.)4 SPDT (snap action) positive-opening switches 
Switching range2x 12,5°, adjustable +/-10°  
2x 18°, fix
 
Cable entry
(included in scope of delivery)
2 x M25 x 1,5 with red transport lock
1x screwed cable gland: sealing area ∅ 10 mm to ∅ 17 mm; 1x dummy screw
 
Utilization categoryAC-15: 230V ; 1,5A
DC-13: 60V; 0,5A
DC-13: 24V; 2A
 
Connection cross section (max.)2,5 mm2 
Protective conductor connectionProtection Class I / protective earthing 
Potential equalization connectionEnclosure / Cover 
Rated insulation voltage Ui250 V 
Rated impulse withstand voltage Uimp2.5 kV, Overvoltage category II, degree of polution 3 
Conventional thermal current Ith6 A 


Ambient conditions according to DIN EN 60947-5-5

Permissible ambient temperature-25 °C …+70 °C 
Protection rating (according to EN 60529)IP 67 


Reliability

 
Contact reliability at AC-15 230V, 1.5 A> 30.000 operations at 100% Ie 

The limit switch HER EX [1] is fastened to a substructure with 2 M8 screws each. It can be mounted on the ends of transport systems. Devices on the transport trolleys actuate the limit switches upon reaching the end of the transport path. (Recommended geometry of the approach setting max. 45° [3].) The roller lever is interchangeable and can be freely fixed on the switch axis. The switching points are cam-controlled and adjustable [2]. The electrical connection is made when the device is open via the cable gland included in the scope of delivery directly to the connection glands of the switching elements.

Note:
The red transport locks must be completely removed and replaced with the supplied screw plugs.

For protection against electrostatic discharge HER EX is provided with conductive compounds and external potential equalization connections to which a minimum of 4 mm2 potential equalization cable must be connected directly to the system. All connections must be checked regularly in accordance with the operation instructions.

Variants

Name Ordering No. Weight ATEX Zone Approvals Contacts
NC
NO
SPDT
HER EX 606 2D 92.096 173.606 2 kg / 1 Unit 21 & 22 L II 2D ATEX , IEC Ex
2 (Au)
HER EX 606 3D 92.096 606.606 2 kg / 1 Unit 22 L II 3D ATEX , IEC Ex
2 (Au)

Downloads

Data sheet – HER EX

PDF3 MB

download