SLR EX

ATEX Limit Switch

Article Number: 2D: 92.069 583.xxx; 3D: 92.098 668.xxx

  • Thermoset housing
  • Brass roller Ø 50 mm
  • Adjustable prewarning
  • Without latching 
    (incl. potential equalization cable)

Features

The SLR EX limit switches are used to monitor the end position of moving machine parts. With at least two switching points a signal can be used for a pre-warning. The SLR EX limit switches are suitable for use in transportation, conveying, loading and mixing systems for bulk materials and are intended for use in fixed installations. In the installation position they are triggered from one side. The KIEPE limit switches Type SLR EX are suited for use in explosive atmosphere with conductive dust, Group II, category 2 , in zone 21 and 22 (Type SLR EX 2D) or category 3, only in zone 22 (Type SLR EX 3D).The Kiepe limit switch Type SLR EX complies with the ATEX Directive 2014/34/EU and meets the safety objectives of the Low Voltage Directive 2014/35/EU and IECEx. The switch Type SLR EX features a robust thermoset housing and is equipped up to 4 force-actuated changeover contacts with snap-action function with two settable switching points.

Note:
The limit switch must only be used in electrical control circuits.

The limit switch type SLR EX operates when the actuating roller is approached and deflected by the machine part in the direction of rotation of the roller lever. The switching angle can be set for each switching contact by means of an adjustable cam roller. In addition to the safety cut-out this also enables an advance warning to be realized. When the machine part is reset, the roller lever returns automatically.

General

Designation Limit Switch Type SLR EX 
Type of actuation Bidirectional (double-side) via roller lever  
Complies withEN 60947-5-1; EN IEC 60079-31; (EN IEC 60079-0) 
Suited for Control units in accordance with DIN EN 60204-1 


ATEX/ IECEx

 
Device group / device categoryII / 2D, 3D;  flammable, conductive dust 
Type of protection Protection through housing 
for Zone 21, 22      SLR EX II 2DL II 2D Ex tb IIIC T85°C Db IP67 
for Zone 22            SLR EX II 3DL II 3D Ex tc IIIC T85°C Dc IP67 
CertificatesEPS 12 ATEX 1 479 X, IECEx EPS 14.0040X 


Mechanics

 
EnclosureThermoset (BMC) 
ColorEnclosure – yellow (similar RAL 1004) 
Actuating leverBrass, Spool: ∅ 50mm 
Deflection of roller lever (max.)+/- 75° 
Mounting4 x M8 
 Weight2.2 kg 


Electrical system

Switching system (max.) 4 SPDT (snap action) positive-opening switches 
Switching range2x 12,5°, adjustable +/-10°
2x 18°, fix
 
Cable entry
(included in scope of delivery)
 2 x M25 x 1,5 with red transport lock
1x screwed cable gland: sealing area ∅ 10 mm to ∅ 17 mm; 1x dummy screw
 
Utilization categoryAC-15: 230 V ; 1,5
DC-13: 60 V; 0.5
DC-13: 24 V; 2 A
 
Connection cross section (max.)2.5 mm2 
Protective conductor connectionProtection Class II / protective insulation 
Potential equalization connectionat lever  
Rated insulation voltage Ui250V 
Rated impulse withstand voltage Uimp2,5 kV, Overvoltage category II, degree of polution 3 
Conventional thermal current Ith6 A 


Ambient conditions according to DIN EN 60947-5-5

Permissible ambient temperature-25 °C …+60 °C 
Protection rating (according to EN 60529)IP65 / IP67 


Reliability

 
Contact reliability at AC-15 230V, 1.5 A> 30.000 operations at 100% Ie 

The limit switch SLR EX [1] is fastened to a substructure with 4 M8 screws each. It can be mounted on the ends of transport systems. Devices on the transport trolleys actuate the limit switches upon reaching the end of the transport path. (Recommended geometry of the approach setting max. 45° [3].)The roller lever is interchangeable and can be freely fixed on the switch axis. The switching points are cam-controlled and adjustable [2].

Important Note:
To protect against electrostatic discharge, the roller lever of the SLR EX must be connected with a potential equalization connection of at least 4 mm2. The potential equalization connection is included in the scope of delivery. All potential equalization connection must be checked regularly in accordance with the operating instructions. The electrical connection is made when the device is open via the cable gland included in the scope of delivery directly to the connection glands of the switching elements.

Variants

Name Ordering No. Weight ATEX Zone Approvals Contacts
NC
NO
SPDT
SLR EX 606 3D 92.098 668.606 1.8 kg / 1 Unit 22 L II 3D ATEX , IEC Ex
2 (Au)

Downloads

Data sheet – SLR EX

PDF884 KB

download