DG
Pulse Transducers- Proximity Sensor
- Inductive
Features
Application
The Kiepe pulse transducer of the DG series are inductive proximity sensors and operate contactless and non-touch. They are particularly suitable for applications where high switching accuracy, long service life, wear resistance and corrosion resistance are required. They are preferably used in conveyor systems to monitor the speed of rotating machine parts and can also be used as position switches. The sensor is intended for use in stationary systems and vehicles. The pulse transducers generate pulse sequences whose frequencies are speed-dependent. The pulse sequences can be used for overspeed or underspeed monitoring with the Kiepe speed monitor type EDW. The Kiepe pulse transducer type DG series conforms to the Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU and RoHS Directive 2011/65/EU.
Note:
Use in safety circuits is not permitted. The use of these devices in applications where the safety of persons depends on their function is not permitted.
Application Areas
Corrosive
- Powder
- Not Suitable
- Gravel
- Not Suitable
- Rubble
- Not Suitable
Non-Corrosive
- Powder
- Not Suitable
- Gravel
- Not Suitable
- Rubble
- Not Suitable
Function
These pulse transducers essentially consist of a transistor oscillator whose high-frequency stray field forms the response zone. When a metallic object is immersed in the effective range of the stray field, the oscillating circuit is short-circuited and its internal resistance becomes highly resistive. The oscillations stop and the current consumption of the encoder decreases. This change in current is evaluated by the Kiepe speed monitors.
Technical Data
| Designation | Impulse Transducer Type DG | |
| Protection rating | IP67 | |
| Connection cross section (max.) | 2,5 mm2 | |
| Mounting | 4 x M6 / L <12 mm | |
| Weight | 1,5 kg | |
| Permissible ambient temperature | -25°C...+70°C |
| Version | Pulse Transducer NAMUR | Pulse Transducer PNP switching | ||
| Type | DG 5 | DG 10 | DGP 5 | DGP 10 |
| Rated operating distance Sn | 5 mm | 10 mm | 5 mm | 10 mm |
| Secured operating distance Sa | ≤ 0,81 x Sn | |||
| Correction factors | St37=1; AI=0,3; stainless steel=0,7; Ms=0,4 | |||
| Hysteresis (max.) | 1-10% | 3-15% | ||
| Housing | DG: CuZn (brass), chrome-plated | CuZn (brass), chrome-plated | ||
| Housing Diameter D | 18 mm | 30 mm | 18 mm | 30 mm |
| Rated operating voltage Ub | - | DC 10-30V | ||
| Rated voltage | (nom.) 8,2 V | - | ||
| Actuated current consumption Non-actuated current consumption | ≤ 1,2 mA | - | ||
| Short-circuit protection | - | yes / clocking | ||
| Switching output | 2-wire, NAMUR | 3-wire, PNP | ||
| Rated operating current Ie (max.) | - | 200 mA | ||
| Voltage drop at Ie (max.) | - | 1,8 V | ||
| No-load current l0 | - | ≤ 15 mA | ||
| Residual current lR | - | ≤ 0,1 mA | ||
| Rated insulation voltage Ui | - | 500 V | ||
| Switching frequenzy (max.) | 1 kHz | 0,5 kHz | 0,5 kHz | |
| Connection Drawing | A | B | ||
Installation
The transducers must be installed in such a way that one or more metal parts (preferably ferrous metals) rotate past the encoder head within the response distance. One pulse is generated per metal part. For lower speeds, pulse multiplication is recommended by symmetrically arranging several metal parts. The metal parts should have at least the same dimensions as the encoder head. To ensure trouble-free operation, the installation conditions of the sensor must be observed. The pulse transducers are fastened with two fastening nuts or using the supplied plastic clamp or weld-on plate.
Variants
| Name | Ordering No. | Weight | Switching Distance Sₙ | Switching Behavior | Diameter |
|---|---|---|---|---|---|
| DG 5 | 96.040 610.105 | 0.2 kg / 1 Unit | 5 mm | Namur (2-Wire) | 18 mm |
| DG 5 TN (-40°C) | 215.36.01.02.10 | 0.2 kg / 1 Unit | 5 mm | Namur (2-Wire) | 18 mm |
| DG 5 TH (100°C) | 215.36.01.02.11 | 0.2 kg / 1 Unit | 5 mm | Namur (2-Wire) | 18 mm |
| DGP 5 | 383.06.07.20.00 | 0.2 kg / 1 Unit | 5 mm | PNP (3-Wire) | 18 mm |
| DG 10 | 96.040 610.110 | 0.3 kg / 1 Unit | 10 mm | Namur (2-Wire) | 30 mm |
| DG 10 L 55mm long | 215.21.02.03.09 | 0.3 kg / 1 Unit | 10 mm | Namur (2-Wire) | 30 mm |
| DG 10 TN (-40°C) | 215.36.01.02.15 | 0.2 kg / 1 Unit | 10 mm | Namur (2-Wire) | 30 mm |
| DG 10 TH (100°C) | 215.36.01.02.16 | 0.2 kg / 1 Unit | 10 mm | Namur (2-Wire) | 30 mm |
| DGP 10 | 383.06.07.03.00 | 0.3 kg / 1 Unit | 10 mm | PNP (3-Wire) | 30 mm |