EDW
Speed MonitorsArticle Number: 93.057 639.001
- Speed monitor for DIN EN rail
- with Plug-In Screw Terminals
Features
Application Areas
Corrosive
- Powder
- Conditionally Suitable
- Gravel
- Conditionally Suitable
- Rubble
- Not Suitable
Non-Corrosive
- Powder
- Suitable
- Gravel
- Suitable
- Rubble
- Not Suitable
Technical Data
| Classification | Speed Monitor with Run-Up Bridge (Low Voltage Switch Gear) |
|---|---|
| Standards | EN 60947-5-1, DIN EN IEC 61000-6-2 DIN EN 61000-6-3, DIN EN IEC 63000 (RoHs) |
| Certificates | CE, RoHs |
| Voltage Supply | Multivoltage |
| Connectable Sensors | 3-Wire-NPN-, PNP-Sensor or 2-Wire-NAMUR-Sensor |
| Output | 1x Change Over Relay Contact |
| Run-Up Bridge | 0 to 60 Seconds, adjustable & manual Start at the Front |
| Switch Hysteresis | Adjustable |
| Status Indicator | LED at Front |
| Connection | 4 Plug-in Terminal Blocks, each with 4 Screw Terminals |
| Wire Cross-Section | 0,5 mm2 ... 2,5 mm2 |
| Operating Temperature | – 40 °C bis + 70 °C, 5 % ≤ rF ≤ 95 % |
| Protection Type Casings / Clamps | IP 20 gem. EN 60529 |
| Shock Resistance (EN 60068-2-27) | 15 g, t = 11 ms |
| Vibration Resistance (EN 60068-2-6) | 0,7 g (3-100 Hz) |
| Mounting | Auf Hutschiene gem. EN 60715 |
| Measurements | 23 mm x 103,6 mm x 123 mm |
| Weight | 0,2 kg |
| Rated Insulation Voltage Ui | AC 230 V |
| Rated Impulse Withstand Voltage Uimp | 2.5 kV |
| Overvoltage Category / Altitude | II / 2000 m a.s.l. NN |
| Degree of Pollution | 2 |
| Voltage Supply | Terminal 3 (+), 4 (-) DC 24 V +/- 15 %, stabilized Terminal 11 (L1), 12 (N) AC 110 V - 240 V +/- 15 %; 50 to 60 Hz |
| Sensor Input 3-Wire-NPN-, PNP-Sensor | Terminal 5 to 8 24 V, max. 50 mA |
| 2-Wire NAMUR-Sensor | According to EN 60947-5-6 (DIN 19234) |
| Frequency Range | 0 to 100 Hz |
| Minimum Impulse Duration | ≥ 2 ms |
| Relay Contact | Klemmen 13, 14, 15 |
| Use Categories | AC-15 / DC-13 |
| Switching Voltage | ≤ 250 V AC / ≤ 2 kVA ≤ 30 V DC / ≤ 30 W |
| Switching Current / Continuous Thermal Current | 8 A (at TU ≤ 35 °C) |
| Switch Hysteresis | 15 % (Default), Adjustable from 3% to 25% |
| Relay Response Time | 200 ms |
| Electrical Operating Life | 1 x 105 Operations |
Installation
The top hat rail enables quick and easy mounting of the switch in the existing control cabinet. The speed monitor is first placed on the top hat rail with the mounting edge and then pressed onto the top hat rail until the catch engages.
Variants
| Name | Ordering No. | Weight | For Type |
|---|---|---|---|
| EDW 600 | 93.057 639.001 | 0.2 kg / 1 Unit | DG, DGP, EOG, DK |